URM1013

Software Product

PRO Indexer

Resolves Incident Number

4611

Comments

Added parameter INSTANCE to the indexing command TRIGGER.

When you check a trigger condition in a given area, and the trigger may be fired more than once, if you need do anythig based on where you find the trigger, i.e the first place a OMR bar is found, then you need to specify the number of occurrence in the trigger command.

The INSTANCE parameter only support the Trigger command in FAPA mode.

Syntax:
TRIGGER ... instance=n; or
TRIGGER ... instance={FIRST|LAST};

where n represents the number of occurrence that the trigger's checking condition is met;
FIRST represents the first place the trigger's checking condition is met, instance=FIRST equals to instance=1;
LAST represents the last place the trigger's checking condition is met.

Release Date

3/31/2010